Installation Diagrams
| Typical Installation without Bench Tank |
|
The above diagram is intended only for Illustration
purposes and cannot be used in place of the detailed instructions |
| Detailed Side-Wall Chimney Installation |
|
| The proper installation of the chimney is critical to insure
adequate draft for the INOV8 waste oil furnace. The ultraviolet
sensor used in this burner will cause a shutdown if smoke,
fumes or ash generated by poorly burning waste oil accumulates
enough to restrict the view of the flame. The stack must be
installed the proper distance above the roof line to avoid
down drafts. Insufficient chimney height or excessive turns
in the flue will decrease the draft to such extent that the
furnace safety system will cause a safety shutdown. Also,
make sure the flue pipe connected to the furnace can be easily
removed and swung out of the way for ease in cleaning. |
| Oil Storage Systems |
|
| Many operational problems can be eliminated if proper care
is taken in setting up an oil storage system. All waste oil
contains substantial amounts of water and sludge, both of
which settle to the bottom of a tank over a period of time.
A storage system that allows sufficient settlement time will
provide trouble free operation. A two-tank system is recommended
allowing one tank to settle while drawing from the other.
A one-tank system will work, but the floating oil pickup assembly,
that is supplied with the INOV8 furnace, must be used. |
| Bench Tank Setup |
|
| Bench tanks are available in sizes ranging from 280 gallons
to 500 gallons. Our standard is a 300-gallon tank with steel
supports, which holds the INOV8 furnace 8 feet above the floor.
Installations using the bench tank are easier than those without
the tank because of the ease in mounting the furnace versus
hanging and the short distance for running the oil supply
line. The bench tank comes fully supplied with all the necessary
fittings for a complete installation. Many states and cities
have additional regulations regarding the storage of waste
or other fuels which may require stricter measures. It is
very important to check with your local fire inspector, or
proper authority, or a qualified tank installer regarding
the requirements in your area. |
The following three items must be adhered to throughout
the installation and ongoing operation of the INOV8 furnace:
- This furnace is listed for commercial and/or commercial
use only. It cannot be used for residential or any other
unauthorized purpose.
- The assembly, installation, adjustment and maintenance
of this equipment must be done by an INOV8 certified (or
otherwise qualified installer), in accordance with the
instructions in the furnace installation manual, and in
compliance with all federal, state and local regulations
regarding environmental control, fuel storage, fire and
electrical standards.
- The INOV8 equipment must be operated to the settings
established in the furnace installation manual and display
on the furnace.
|